JZJ2B series roots water ring vacuum unit 2-2

JZJ2B series Roots water ring vacuum unit

JZJ2B series.pdf


Summary:

JZJ2B Roots series water ring unit is consists of ZJ type roots pump as the main pump,2BV/2BE1 series of water ring pump or Roots--water ring unit as a fore pump pumping unit. It can be used to pumping gas in addition to, can also aspirate containing water, compared to organic solvent or a small amount of dust gas. And general mechanical vacuum pump, not afraid of oil pollution, not afraid of water, gas and dust, and compared with the general water ring vacuum pump, with vacuum high and pump speed characteristics under high vacuum condition.


Due to the adoption of the high efficiency and energy saving of 2BV series water ring pump before the class, so JZJ2B series vacuum unit than jzj2s series with high efficiency, compact structure, no leakage (2BV pump mechanical seal design, different to 2SK series packing seal) resistance to corrosion (2BV adopts stainless steel or aluminum bronze impeller)protection grade higher merit.


Roots vacuum pump using the company's own R & D ZJ Roots series vacuum pump,our company will pump cavity and the bearing cavity sealing was improved after the ZJ Roots series vacuum pump in the pumping process of a large number of water vapor and various solvents oil pump is not easy to be emulsified.


Roots water ring vacuum unit of pump working fluid with water, can also be used in organic solvents (methanol, alcohol, xylene, acetone and other organic solvent ) or other liquid, using pre - pump as a closed circulation system,can greatly reduce the pollution to the environment, and greatly improve the recovery of the organic solvent. The limit vacuum degree by the working fluid saturated vapor pressure.

 

Roots unit selection considerations:

.Learn to be pumping gas composition, gas containing excluding condensable vapor, dust particles, there is no corrosion. The choice of vacuum pump and need to know the gas composition, the selection of the corresponding pump was pumping gas. If the gas containing steam, particles, and corrosive gases should be the consideration in the pump inlet pipe to install auxiliary equipment, such as condensers, dust collector.


. Roots vacuum unit of the working pressure should meet the requirements of vacuum equipment vacuum and pressure. Such as a vacuum drying process requirements 10mmhg (absolute pressure) of the working pressure, the selection of vacuum pump limit pressure at least 2mmhg, preferably below. Usually choose the limit pressure of the pump is higher than that of vacuum pressure equipment of one half to one order of magnitude.


.Correctly choose the normal operating range of the working point of the roots vacuum units. Roots vacuum unit for maximum suction pressure limit pressure *. Example: the normal operating range of JZJ2B150-2.1Roots water ring vacuum unit for: 6000Pa~125Pa. The scope of work as the main pump is turned on normal working pressure range, the unit in the scope of work within the best efficiency.


.Under the pressure of the vacuum unit, the vacuum unit should be able to discharge all the gas generated in the process of vacuum equipment.


. Choose the appropriate unit configuration. According to the practical conditions. For example: JZJ2B300-4.1 unit and JZJ2B300-2.1 unit maximum pumping speed and ultimate pressure is the same, the difference is their work scope and power consumption, the normal working range of JZJ2B300-4.1 unit is 2000Pa~125Pa, and the normal working range of JZJ2B300-2.1 unit 5000Pa~125Pa. obviously JZJ2B300-2.1 units work in a wider range, but its power consumption is greater. If we can confirm the pumping system working pressure is less than 2000Pa, should be preferred JZJ2B300-4.1 group to save energy. But if there is a strong demand for fore pumping unit and unit takes a long time to work at high pressure the system is used JZJ2B300-2.1 the fore pump unit has more appropriate.


Model representation method


For example:J Z J 2 B 1 5 0 - 2 . 1


J-denotes the first letter of the unit

ZJ-denotes the main pump using ZJ Roots series vacuum pump

2B-denotes the fore pump using the 2BV/2BE series water(or liquid) ring vacuum pump

("2S" denotes the fore pump using the 2SK series water (or liquid) ring vacuum pump 

150-denotes the suction speed of the main pump (Roots pump) L/s

2.1-denotes code of the suction speed ratio

(i.e. the suction speed ratio between the main pump and the secondary pump is 2; the suction speed ratio between the secondary pump and the fore pump is 1.) 

 

JZJ2B Series Roots Water Ring Vacuum Unit Technical Specifications:


Unit type

pump type

suction speed(L/s)

Max. suction pressure(Pa)

Limited vacuum (Pa) abs

Total power(kW)

main pump

fore pump

water ring

oil ring

JZJ2B15-2

ZJ15

2BV2060

15

8000

    267

    80 

1.65

JZJ2B30-2

ZJ30

2BV2061

30

8000

2.25

JZJ2B30-1

ZJ30

2BV5110

30

12000

4.75

JZJ2B70-2

ZJ70

2BV5110

70

6000

5.5

JZJ2B70-1

ZJ70

2BV5111

70

12000

7

JZJ2B150-2A

ZJ150

2BV5111

150

6000

8.5

JZJ2B150-2B

ZJ150

2BV5121

150

8000

10.5

JZJ2B150-1

ZJ150

2BV5131

150

10000

14

JZJ2B300-2A

ZJ300

2BV5131

300

4000

15

JZJ2B300-2B

ZJ300

2BV5161

300

5000

19

JZJ2B300-1

ZJ300

2BE1 202

300

10000

26

JZJ2B600-2A

ZJ600

2BE1 202

600

4000

29.5

JZJ2B600-2B

ZJ600

2BE1 203

600

5000

44.5

JZJ2B600-1

ZJ600

2BE1 252

600

12000

52.5

JZJ2B1200-2A

ZJ1200

2BE1 252

1200

2500

60

JZJ2B1200-2B

ZJ1200

2BE1 253

1200

4000`

90

JZJ2B1200-1

ZJ1200

2BE1 303

1200

8000

125

JZJ2B2500-2

ZJ2500

2BE1 303

2500

3000

132

JZJ2B30-2.1

ZJ30

ZJ15/2BV2061

30

8000

  25

  0.8 

2.8

JZJ2B70-2.1

ZJ70

ZJ30/2BV5110

70

6000

6.25

JZJ2B150-2.1

ZJ150

ZJ70/2BV5111

150

6000

10

JZJ2B150-4.1

ZJ150

ZJ30/2BV5110

150

3000

7.75

JZJ2B300-2.1

ZJ300

ZJ150/2BV5131

300

5000

18

JZJ2B300-2.2

ZJ300

ZJ150/2BV5121

300

4000

14.5

JZJ2B300-4.1

ZJ300

ZJ70/2BV5111

300

2000

11

JZJ2B600-4.1

ZJ600

ZJ150/2BV5131

600

1500

21.5

JZJ2B600-2.2

ZJ600

ZJ300/2BV5161

600

2000

26.5

JZJ2B1200-4.2

ZJ1200

ZJ300/2BV5161

1200

1000

34

JZJ2B1200-4.1

ZJ1200

ZJ1200/2BE1 202

1200

1200

41

JZJ2B1200-2.2

ZJ1200

ZJ600/2BE1 203

1200

2500

59.5

JZJ2B1200-2.1

ZJ1200

ZJ600/2BE1 252

1200

3000

67.5

JZJ2B2500-4.1

ZJ2500

ZJ600/2BE1 252

2500

1000

74.5

JZJ2B30-2.1.1

ZJ30

ZJ15/ZJ15/2BV2061

30

8000

 0.5

 0.05

3.35

JZJ2B70-2.2.1

ZJ70

ZJ30/ZJ15/2BV2061

70

4000

4.3

JZJ2B70-2.1.1

ZJ70

ZJ30/ZJ30/2BV5110

70

6000

7

JZJ2B150-2.2.1

ZJ150

ZJ70/ZJ30/2BV5110

150

3000

9.25

JZJ2B300-2.2.1

ZJ300

ZJ150/ZJ70/2BV5111

300

3000

14

JZJ2B300-4.2.1

ZJ300

ZJ70/ZJ30/2BV5110

300

1200

10.25

JZJ2B600-2.2.1

ZJ600

ZJ300/ZJ150/2BV5131

600

2500

25.5

JZJ2B600-4.2.1

ZJ600

ZJ150/ZJ70/2BV5111

600

1200

17.5

JZJ2B1200-4.2.1

ZJ1200

ZJ300/ZJ150/2BV5131

1200

1000

33

JZJ2B2500-4.2.1

ZJ2500

ZJ600/ZJ300/2BE1 202

2500

1000

55.5

JZJ2B5000-4.2.1

ZJ5000

ZJ1200/ZJ600/2BE1 252

5000

800

104.5

JZJ2B10000-4.2.1

ZJ10000

ZJ2500/ZJ1200/2BE1 303

10000

800

202


Explanation:

2.As the technology parameter of the each pump, please refer to the single pump parameter.  

1. The above table refers to the standard series. Because under the various practical conditions, the suction gases and its pressure will have great difference. The practical pumping process, the gas releasing process, the coagulation situation and the time variety should be considered when choose the package unit. Otherwise, refer to the existing equipments. 

3. Please inform us when the motor of the pump, the electric connecting point vacuum meter and the electric control cabinet need explosive-proof. Further, the2BV5 series vacuum pumps are also replaced by the 2BV6 series pumps.  

4. As the maximum suction pressure, please refer to the highest pressure that enables the main pump work. If the main pump works under the max suction pressure, it may be overloaded.


Leave a Reply

Your email address will not be published. Required fields are marked *

SUBMIT

Related Recommendations

PRODUCTS

Leave a Reply

Your email address will not be published. Required fields are marked *

SUBMIT